Hantek DSO5202P Digital Oscilloscope 200MHz 1GSa/s 2 Channels 7inch TFT LCD PC USB Electrical Tool - NSE Imports Hantek DSO5202P Digital Oscilloscope 200MHz 1GSa/s 2 Channels 7inch TFT LCD PC USB Electrical Tool - NSE Imports
Hantek
Ships from: ChinaShips from China to most countries
Hantek DSO5202P Digital Oscilloscope 200MHz 1GSa/s 2 Channels... £388.95
The Hantek DSO5202P brings you a range of great features to allow you to measure, trace and record your electrical issues. Ideal for Diagnostic and Repair work, the ability to either record your data to USB or connect to your PC for live data capture gives you a range of flexibility. With its large 7 inch WVGA display you can see results clearly. Hantek digital oscilloscopes offer an excellent price/performance ratio.The DSO 5000 series offers twelve versions of digital oscilloscopes with 60, 70, 100 and 200 MHz bandwidths. The main features of the DSO 5202P model are the 1GS/s maximum sampling rate, 24K sampling memory, USB host on the front USB panel (data storage possibility), connectivity for long-distance control by PC (software included) and external trigger. The pack includes two 60 MHz passive probes 1:1 and 10:1 suitable for most tasks.Use our info link at the top of the description to get the latest software. We will send you links for the latest software upon purchase. Features: 200MHz bandwidths. 1GSa/s Real Time sample rate. Large (7.0-inch) color display,WVGA(800x480). Record length up to 40K. Trigger mode: edge/pulse width/line selectable video/slop/overtime etc. USB host and device connectivity, standard. 32 automatic measurements. Four math functions, including FFTs standard. Supplied with MSScope software for PC real-time analysis. Specifications: Click to view Full Specifications × Model DSO5202P DSO5102P DSO5072P Acquisition Sample Rate Real-Time Sample: 1GS/s Equivalent Sample: 25GS/s Acquisition Modes Normal Normal data only Pea'k Detect High-frequency and randon glitch capture Average Waveform Average, selectable 4,8,16,32,64,128 Inputs Inputs Coupling AC, DC, GND Inputs Impedance 1MΩ±2% II20pF±3pF Probe Attenuation 1X, 10X Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: rated at 20dB/decade above 100kHz to 13V Peak AC at 3MHz* and above. For non-sinusoidal waveforms, Peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. Horizontal Sample Rate Range 500MS/s--1GS/s Waveform Interpolation (sin x)/x Record Length 40'K SEC/DIV Range DSO5202P4ns/div to 40s/div DSO5102P/DSO5072P4ns/div to 40s/div Sample Rate and Delay Time Accuracy ±50ppm(at over any ≥1ms time interval) Position Range DSO5202P2ns/div to 10ns/div;(-4div x s/div) to 20ms; DSO5102P/DSO5072P20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s Incremental Time Measurement Accuracy (Full Bandwidth) Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 Vertical Vertical Resolution 8-bit resolution, all channel sampled simultaneously Position Range 2mV/div to 200mV/div, ±2V 200mV/div to 5V/div, ±50V Bandwidth DSO5202P100MHz DSO5102P100MHz DSO5072P70MHz Rise Time at BNC( typical) DSO5202P3.5ns DSO5102P3.5ns DSO5072P5ns Analogue Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled 2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div, ±50V Math +, -, *, /, FFT FFT Windows: Hanning, Flatop, Rectangular, Bartlett, Blackman; 1024 sample point Bandwidth Limit 20MHz Low Frequency Response (-3db) ≤10Hz at BNC DC Gain Accuracy ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div DC Measurement Accuracy, Average Acquisition Mode When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions Trigger System Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative Trigger Source CH1, CH2, EXT, EXT/5, AC Line Trigger Modes Auto, Normal, Single Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject Trigger Sensitivity (Edge Trigger Type) DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz Trigger Level Range CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); Set Level to 50%(typical) Operates with input signals ≥50Hz Video Trigger Video Trigger Type CH1, CH2: Pea'k-to-Pea'k amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line Holdoff Range 100ns ~ 10s Pulse Width Trigger Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width Pulse Width Range 20ns ~ 10s Slope Trigger Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. Time Range 20ns ~ 10s Overtime Trigger Over Time Mode Rising edge or Falling edge Time Range 20ns ~ 10s Alternative Trigger Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope Trigger Frequency Counter Readout Resolution 6 digits Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors) Frequency Range AC coupled, from 4Hz Min to rated bandwidth Signal Source Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as trigger able events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work. Measure Cursor Measurement Voltage difference between cursors: ΔV Time difference between cursors: ΔT Reciprocal of ΔT in Hertz (1/ΔT) Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Min, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF Display Display Type 7 inch 64K color TFT (diagonal liquid crystal) Display Resolution 800 horizontal by 480 vertical pixels Display Contrast Adjustable (16 gears) with the progress bar Probe Compensator Output Output Voltage( typical) About 5Vpp into ≥1MΩ load Frequency(typical) 1kHz Power Supply Supply Voltage 100-120VACRMS(±10%), 45Hz to 440Hz, CATII 120-240VACRMS(±10%), 45Hz to 66Hz, CATII Power Consumption <30W Fuse 2A, T rating, 250V Environmental Temperature Operating: 32F to 122F (0C to 50C); Non-operating: -40F to 159.8F (-40C to +71C) Cooling Method Convection Humidity +104F or below (+40C or below): ≤90% relative humidity; 106F to 122F (+41C to 50C): ≤60% relative humidity Altitude Operating: Below 3,000m (10,000 feet); Non-operating: Below 15,000m(50,000 feet) Mechanical Size Length 385mm, Width 200mm, Height 245mm Weight 3.5KG(with Packing); 2.08KG(without Packing)

Free Tracked Shipping*

*Some countries may have a small delivery charge due to disproportionately high shipping.

Fully secured payments

All our payments are handled by secure methods, we'll never see or ask for your payment details.

Friendly service

We pride ourselves on great service, no matter the order value, we want you to be satisfied with it.