Ships from: China
Hantek 2000 series 3-in-1 Digital Oscilloscope Waveform Generator Multimeter Portable USB 2 Channels 40/70mhz
from £127.95
The Hantek 2000 handheld oscilloscope series provide a lightweight and compact 3 in 1 multifunction tester: Multimeter, Oscilloscope, Signal source / Waveform generator (2Dxx models only). Their small volume allows handheld operation, with an integrated desk stand featuring multi-angle adjustment for when you're at the bench. Ultra-low-power consumption with a USB Type-C charging interface, each 2 hours battery charge allow working one full day of use or standby for around two months. The High-definition colour LCD screen displays your readings clearly; Minimalist keyboard design simplifies operation. The USB connectivity feature allows your PC to measure and record in real-time.
Please note: Only the 2Dxx models feature the Signal/Waveform generator feature.Use our info link at the top of the description to get the latest software.
We will send you links for the latest software upon purchase.
Features:
40 (2x4x models) or 70MHz (2x7x models) bandwidth.
250MSa/s Real Time sample rate.
Oscilloscope + Waveform Generator + Multimeter: This multi-purpose station own three universal test instrument functions. It is outgoing right-hand product for engineers.
Intelligent charging control: Its lithium batteries can be recharged by either high current-5V/2A or ordinary computer USB interface. Allow while charging, while using, very convenient and handy;
Ultra-low power design: Type C charging interface, after every recharge of 2 hours, the device can be used continuously for a full day or standby more than two months;
Large-capacity lithium battery power supply: 18650 replaceable lithium battery power system, free from replace battery;
5V/2A charger + Type C charging cable: Type C power + data transfer interface, can share the charger and data cable with your mobile phone;
AUTO one-key test: Magic tool and essential function for test newbie;
Volume small, one hand holding: The 45 degree suspension bracket design provide you a work station anywhere anytime; One key page out, quick compare two groups of reference waveforms + 6 groups of waveforms storage, simple and effective;
Digital voltmeter function: automatic frequency and amplitude measurement, convenient and worry-free; Its cursor measurement function supports time and voltage manual measurement, and measure the required waveforms accurately; One-click switching its Chinese and English language menu;
Colour LCD screen: exquisite and smooth lines make the waveforms clear and undistorted when magnify; Minimalist keyboard design simplify operation, convenient to use;
Unibody casing: fine touch feeling, favourable impact resistance, outstanding heat resistance, easy to disassemble;
Self-calibration function: free from level drift after long time unused;
Universal multimeter function: voltage, current, resistance, diode, capacitor, on-off test;
Waveform generator output function (2Dxx models only): output sine, square, triangle, trapezoidal and other waveforms; sine up to 25MHz;
Video help: Scan to QR code on back of machine to get help and video courses.
The PC software supports Windows 7/8/10 32-bit and 64-bit.
Specifications:
Click to view
Full Specifications
×
The included power adapter is a 5V/2A USB Charger, if your country uses a different plug any USB charger of the same rating will be fine
Model
Hantek2D72
Hantek2D42
Hantek2C72
Hantek2C42
Oscilloscope Mode
Bandwidth
70MHz
40MHz
70MHz
40MHz
Channel
2CH+DMM+AWG
2CH+DMM+AWG
2CH+DMM
2CH+DMM
Horizontal
Sample Rate Range
250MSa/s(Single-channel), 125MSa/s(Dual-channel)
Waveform Interpolation
(sin x)/x
Record Length
Max. 6K for single-channel; 3K samples per dual-channel
SEC/DIV Range
5ns/div~500s/div 1, 2, 5 sequence
Vertical
A/D Converter
8-bit resolution,each channel sampled simultaneously
VOLTS/DIV Range
10mV/div~10V/divat input BNC
Bandwidth Limit, typical
20MHz
Low Frequency Response (-3db)
≤10Hz at BNC
Rise Time at BNC, typical
≤5ns
DC Gain Accuracy
±3% for Normal or Average acquisition mode, 10V/div to 10mV/div
Note: Bandwidth reduced to 6MHz when using a 1X probe.
Acquisition
Acquisition Modes
Normal
Trigger
Type
Edge
Mode
Auto, Normal, single
Level
±4 divisions from center of screen
Trigger Level Accuracy
0.2div × volts/div within ±4 divisions from center of screen
Slope
Rising, Falling, Rising & Falling
Source
CH1/CH2
Input
Coupling
DC, AC or GND
Input Impedance,
25pF±3 pF, 1MΩ±2%
DC coupled
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factors
1X, 10X, 100X, 1000X
Maximum Input Voltage
150VRMS
Measurement
Cursor
Voltage difference between cursors: △V
Time difference between cursors: △T
Automatic Measurements
Frequency, Amplitude
Arbitrary Waveform Generator Mode
Waveform Frequency
Sine: 1Hz~25MHz
-
-
Square: 1Hz~10MHz
-
-
Ramp: 1Hz~1MHz
-
-
EXP: 1Hz~5MHz
-
-
Sampling
250MSa/s
-
-
Amplitude
2.5Vpp(50Ω)
-
-
5Vpp(High impedance)
-
-
Frequency Resolution
0.10%
-
-
Channel
1CH waveform output
-
-
Waveform Depth
512Sa
-
-
Vertical Resolution
12 bit
-
-
Output Impedance
50 Ω
-
-
DMM
Maximum Resolution
4000 Counts
DMM Testing Modes
Voltage,Current,Resistance,Capacitance,Diode &On-Off
Maximum Input Voltage
AC:600V, DC: 600V
Maximum Input Current
AC: 10A, DC:10A
Input Impedance
10MΩ
Measurement Term
Range
Accuracy
Resolution
DC Voltage
400.00mV
± (0.8% + 5)
100uV
4.000V
1mV
40.00V
10mV
400.0V
100mV
600.0V
± (1% + 2)
1V
Overload protection: 400mV: 250V, other: 600Vrms.
AC Voltage
4.000V
± (1.2% + 5)
1mV
40.00V
10mV
400.0V
100mV
600.0V
±(1.5% + 5)
1V
Frequency: 40Hz~400Hz;
Frequency of 400V and 600V: 40Hz~100Hz
DC Current
40.00mA
± (1% + 2)
10uA
200.0mA
± (1.5% + 2)
100uA
4.000A
± (1.8% + 2)
1mA
10.00A
± (3% + 2)
10mA
Overload protection:
self restoring fuse: 200mA/250V, 4A and 10A range no fuse.
AC Current
40.00mA
± (1.3% + 2)
10uA
400.0mA
± (1.8% + 2)
100uA
4.000A
± (2% + 3)
1mA
10.00A
± (3% + 5)
10mA
Frequency: 40Hz~400Hz;
self restoring fuse: 200mA/250V, 4A and 10A range no fuse.
Resistance
400.0Ω
±(1% + 3)
0.1Ω
4.000KΩ
±(1.2% + 5)
1Ω
60.00KΩ
10Ω
400.0KΩ
100Ω
4.000MΩ
1KΩ
40.00MΩ
± (1.5%±3)
10KΩ
Overload protection: 220Vrms
Capacitance
40.00nF
±(3% + 5)
10pF
400.0nF
100pF
4.000uF
1nF
40.00uF
10nF
100.0uF
100nF
Overload protection: 220Vrms
Diode
0V~1.0V
On-Off
<50Ω
General Specifications
Display
Display Type
2.8 inch64K color TFT
Display Resolution
320 horizontal by 240 vertical pixels
Display Contrast
Adjustable
Power Supply
Supply Voltage
100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A
Power Consumption
<2.5W
Fuse
T, 3A
Battery
2600mA*2
Environmental
Operating Temperature
0~50 °C (32~122 °F)
Storage Temperature
-40~+71 °C (-40~159.8 °F)
Humidity
≤+104℉(≤+40°C): ≤90% relative humidity
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity
Cooling Method
Convection
Altitude
Operating and
3,000m (10,000 feet)
Nonoperating
Mechanical Shock
Random Vibration
0.31gRMS from 50Hz to 500Hz, 10 minutes on each axis
Nonoperating
2.46gRMS from 5Hz to 500Hz, 10 minutes on each axis
Operating
50g, 11ms, half sine
Mechanical
Dimension
199 x 98x 40mm (L x W x H)
Weight
624g
Standard Accessories
Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1
Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1
Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1
Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1
Additional Images:
Click to view
Additional images
×
Great function with small size!: Minimalist keyboard design simplify operation, easy to use.
Oscilloscope + Waveform Generator + Multimeter: Multi-purpose station own three universal test instrument functions. Outgoing right-hand product for engineers.
Waveform Generator Function (2Dxx models only): A multi-purpose instrument that helps complete your tasks more quickly, improves work efficiency, and meets all your current and future test needs.
Multifunction Digital Multimeter Function: High sensitivity and accuracy, showing clear, strong anti-overload capability, easy to carry.
Intelligent Charging Control: Be able to recharged by 5V/2A large current or ordinary computer USB port, measurement can be done even while charging, convenience and user-friendly.
Large-capacity Lithium Battery + Ultra Low Power + Type C Data Transfer/Charging Interface: 18650 replaceable lithium battery power system, free from replace battery; Able to be recharged by 5V/2A large current or ordinary computer USB port, able to use while charging, very convenient and handy; USB Type-C charging interface, after every recharge of 2 hours, the device can be used continuously for a full day or standby more than two months; USB Type-C power + data transfer interface, can share the charger and data cable with your mobile phone;
Interface layout
Powerful PC software: Oscilloscope powerful functions: 20 kinds of automatic measurement, cursor measurement, waveform printing and saving functions, REF and Math functions, Pass / Fail functions.
The waveform generator is able to draw and output arbitrary waveforms on its PC software
Its multimeter with recorder function, which support the measurement results to generate the curves and analyse them.
Ships from: China
Hantek DSO2D10 Digital Oscilloscope 2CH+1CH Digital Storage 1GS/s Sampling Rate 100MHz Bandwidth Dual Channel
£209.95
£231.95
The Hantek DSO2D10 is a cost-effective oscilloscope that offers a wide range of features and specifications, making it ideal for both beginners and advanced users. With a bandwidth of 150 MHz, a sample rate of 1 GSa/s, and a memory depth of 8 M, the DSO2D10 can capture and analyze even the most complex signals.
The DSO2D10 also features a built-in waveform generator, which can be used to create test signals for troubleshooting and debugging. The scope also supports 14 trigger modes, standard with 5 kinds of serial protocol triggers and decodes, and 32 kinds of auto measurements with statistics.
In addition to its powerful oscilloscope features, the DSO2D10 also includes a 3-digit digital voltage meter and a 6-digit hardware frequency indicator. It also has 2 sets of DVM and abundant SCPI remote command control.
The DSO2D10 is a versatile tool that can be used in a variety of fields, including communication, aerospace, embedded systems, computers, research, PCB repair, and education. It is a valuable addition to any engineer's toolkit.
Use our info link at the top of the description to get the latest software.
We will send you links for the latest software upon purchase.
Features:
2 channels, each channel has independent knob control;
Analog bandwidth 100MHZ
The highest sampling rate is 1 GSa/s;
The storage depth is 8Mpts;
The vertical range 2mV/div ~ 10V/div;
Built-in a 25MHz signal generator;
Vertical resolution: 8bit;
Trigger: edge, pulse, video, slope, timeout, window, pattern, interval, runt, UART, LIN, CAN, SPI, IIC;
Bus decoding and protocol analysis: RS232/UART, I2C, SPI, CAN, LIN;
Can save settings, waveforms, reference waveforms, CSV, pictures and other data formats.
3-digit digital voltmeter and 6-digit frequency meter functions;
Support 32 kinds of automatic measurement and statistics functions, real-time statistics of minimum, maximum, standard deviation and other statistical information;
Two sets of digital voltmeter functions;
Support threshold test to realize free measurement in the screen;
Rich SCPI remote control instructions;
Able to connect to a PC over USB for live data capture and logging
Able to store data on a USB Stick for later inspection
Package includes: 1 X Hantek DSO2D10 Digital Oscilloscope, 1 x Probe, 2 x BNC to Alligator Clip Test Cables, 1 x Power Cable, 1 x USB Cable
These run on 110V-240V AC We will send an appropriate power lead for your country.
Specifications:
Click to view
Full Specifications
×
Model
DSO2D15
DSO2D10
DSO2C15
DSO2C10
Bandwidth
150MHz
100MHz
150MHz
100MHz
Oscilloscope channels
2CH
2CH
2CH
2CH
Waveform generator
1CH
1CH
-
-
Oscilloscope
Sample rate
1GSa/s (single channel) 500MSa/s (two channels)
Acquisition
Normal
Sample data
Peak-to-peak value
Display high frequency and random burr
Average
Average waveform, times: 4, 8, 16, 32, 64, 128
High resolution
Up to 12bit
Input
Input coupling
DC, AC, GND
Input impedance
1MΩ±2% ‖20pF±3pF
Probe attenuation factor
1X, 10X, 100X, 1000X
Voltage rating
300V CAT II
Maximum input voltage
300VRMS (10X)
Horizontal
Waveform interpolation
(sin x)/x
Maximum record length
Single channel maximum 8M
Two channels maximum 4M
Horizontal scale range
2ns/div~100s/div 1, 2, 5 step by step
Time base mode
Y-T, X-Y, Roll
Zero offset
±0.5 div*minimum time base gear
Sample Rate and Delay Time Accuracy
±25ppm
Delta Time Measurement Accuracy (Full Bandwidth) Sample Rate and Delay Time Accuracy
single-shot, Normal mode ±(1 sample interval+100ppm×reading+0.6ns)
>16 times averages ±(1 sample interval+100ppm×reading+0.4ns)
Sample interval=sec/div÷200
Sample Rate and Delay Time Accuracy
±50ppm(at any interval greater than 1ms)
Vertical
Model
DSO2D15
DSO2D10
DSO2C15
DSO2C10
Bandwidth
150MHz
100MHz
150MHz
100MHz
Rising time in BNC position (typical)
2.4ns
3.5ns
2.4ns
3.5ns
Vertical resolution
8 bits resolution, each channel samples simultaneously
Vertical sensitivity
2mV/div to 10V/div
Offset range
≥ 200mV/div, ±1V;
<200mV/div ±50V
Mathematical operation
+, -, ×, ÷, FFT
FFT
Window: Rectangle, Hanning, Hamming, Blackman, Bartlett, Flattop
Bandwidth Limit
20MHz
Bass response(-3db)
In BNC position ≤ 10Hz
Vertical gain accuracy
In ''normal'' or ''average'' acquisition mode, the accuracy of 10V/div to 10mV/div is ±3%;
In ''normal'' or ''average'' acquisition mode, the accuracy of 5mV/div to 2mV/div is ±4%
Note: Bandwidth reduced to 6MHz when using a 1X probe
Trigger
Trigger type
Edge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC
Trigger level range
±5 divisions from the center of the screen
Trigger mode
Auto, Normal, single
Level
CH1~CH2
±4 divisions from the center of the screen
EXT(Only With AWG Model)
0~3.3V
Holdoff range
8ns~10s
Trigger level accuracy
CH1~CH2
0.2 div×volts/div within ±4 divisions from the center of the screen
EXT(Only With AWG Model)
±(Set value× 6%+40mV)
Edge trigger
Slope
Rising edge, falling edge, rising or falling edge
Signal source
CH1, CH2, EXT(Only With AWG Model)
Pulse width trigger
Polarity
Positive polarity, negative polarity
Condition(When)
<, >, !=, =
Signal source
CH1~CH2,
Pulse width range
8ns ~ 10s
Accuracy
8ns
Video trigger
Signal standard
NTSC, PAL
Signal source
CH1~CH2
Synchronization
Scanning line, line number, odd field, even field, all field
Slope trigger
Slope
rising, falling
Condition(When)
<, >, !=, =
Signal source
CH1 ~ CH2
Time range
8ns ~ 10s
Accuracy
8ns
Overtime trigger
Signal source
CH1~CH2,
Polarity
Positive polarity, negative polarity
Time range
8ns ~ 10s
Accuracy
8ns
Window trigger
Signal source
CH1~CH2
Pattern trigger
Pattern
0: low level; 1: high level; X: ignore
Level(signal source)
CH1~CH2
Interval trigger
Slope
rising, falling
Condition(When)
<, >, !=, =
Signal source
CH1~CH2
Time range
8ns ~ 10s
Accuracy
8ns
Under Amp trigger
Polarity
Positive polarity, negative polarity
Condition(When)
<, >, !=, =
Signal source
CH1~CH2
Time range
8ns ~ 10s
Accuracy
8ns
UART trigger
Condition(When)
Start, Stop, data, Parity ERR, COM ERR
Signal source(RX/TX)
CH1~CH2
Data format
Hex (hexadecimal)
Data length
1 byte
Data bit width
5 bit, 6 bit, 7 bit, 8 bit
Odd-even check
none, odd, even
Idle level
high, low
Baud rate (optional)
110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s
Baud rate(user-defined)
300bit/s~334000bit/s
LIN trigger
Condition(When)
Interval field, synchronization field, ID field, synchronization error, identifier, ID and data
Signal source
CH1~CH2
Data format
Hex (hexadecimal)
Baud rate (optional)
110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s
Baud rate(user-defined)
300bit/s~334000bit/s
CAN trigger
Condition(When)
Start bit, remote frame ID, data frame ID, frame ID, data frame data, error frame, all errors, ACK Error, overload frame
Signal source
CH1~CH2
Data format
Hex (hexadecimal)
Baud rate (optional)
10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000
Baud rate(user-defined)
5kbit/s~1Mbit/s
SPI trigger
Signal source
CH1~CH2
Data format
Hex (hexadecimal)
Data bit width
4, 8, 16, 24, 32
IIC trigger
Signal source (SDA/SCL)
CH1~CH2
Data format
Hex (hexadecimal)
Data index
0~7
When(condition)
Start bit, stop bit, No Ack, address, restart, address and data
Measurement
Cursor
Voltage difference between cursors △V
Time difference between cursors △T
Reciprocal of △T, in Hertz (1/△T)
Auto measurement
frequency, period, mean, peak-to-peak, RMS, minimum, maximum, rising time, falling time, + width, - width, base, top, middle, amplitude, overshoot, preshoot, rising edge phase difference, falling edge phase difference, + duty, - duty, period mean, PRMS, FOVshoot, ROVshoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
DVM
Data source
CH1, CH2
Measurement type
DC RMS
AC RMS
DC
Frequency meter
hardware 6 bits frequency meter
Arbitrary waveform generator
Channel
1
Sample rate
200MSa/s
Vertical resolution
12 bits
Maximum frequency
25 MHz
Standard waveforms
sine, square, ramp,Exp, noise, DC
Arbitrary waveform
Arb1, Arb2, Arb3, Arb4
Sin
Frequency range
0.1Hz~25MHz
Square/pulse
Frequency range
0.1Hz~10MHz
Triangular wave
Frequency range
0.1Hz~1MHz
Sampling wave
Frequency range
0.1Hz~1MHz
Index
Frequency range
0.1Hz~5MHz
Noise
Arb1
Frequency range
0.1 Hz to 10 MHz
Arb2
Frequency range
0.1 Hz to 10 MHz
Arb3
Frequency range
0.1 Hz to 10 MHz
Arb4
Frequency range
0.1 Hz to 10 MHz
Waveform length
4KSa
Frequency
Accuracy
100 ppm (<10 kHz) 50 ppm (>10 kHz)
Resolution
0.1 Hz or 4 bits,take the greater one
Amplitude
Output range
10mV~7Vp-p (high impedance)
5mV~3.5Vp-p (50Ω)
DC offset
Range
±3.5 V, high impedance
±1.75 V, 50 Ω
Resolution
100 μV or 3 bits, take the greater one
Accuracy
2% (1 kHz)
Output impedance
50 Ω
General specifications
Display
Display type
7'' diagonal TFT liquid crystal
Display resolution
800 (horizontal)*480 (vertical) pixels
Display colour
16 million colours (24 bits true colour)
Persistence time
minimum, 1 s, 5 s, 10 s, 30 s, infinite
Display type
dot, vector
Display brightness
adjustable
Grid type
adjustable
Grid brightness
adjustable
Interface
Standard interface
USB Host,USB Device
General specifications
Probe compensator output
Output voltage, typical
about 2Vpp input ≥1MΩ load
Frequency, typical
1kHz
Power supply
100-120VACRMS(±10%), 45Hzto 440Hz, CATⅡ
120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
Power consumption
<30W
Fuse
T, 3.15A, 250V, 5x20mm
Operating temperature
0~50 °C (32~122 °F)
Storage temperature
-40~+71 °C (-40~159.8 °F)
Humidity
≤+104℉(≤+40°C): ≤90% relative humidity
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity
Altitude
Operating and non-operating
3, 000m (10, 000 feet)
Mechanical shock
Random vibration
0.31 g RMS from 50Hz to 500Hz,
10 minutes on each axis
Non-operating
2.46g RMS from 5Hz to 500Hz,
10 minutes on each axis
Operating
50g, 11ms, half-sine wave
Mechanical
Size
318 x 110 x 150mm (length x width x height)
Weight
1900g
Additional Images:
Click to view
Additional images
×
In use screen captures
1CH 25MHz waveform generator, support arbitrary waveform burst output, support modulation waveform output
32 kinds of auto measurements with statistics
Can save 10 sets of reference waveforms, CSV waveforms and settings. The USB one-click screenshot function.
2 sets of DVM, 3-digit digital voltage meter and 6-digit hardware frequency indicator functions
Serial bus trigger and decode, with the protocol monitoring function
8M memory depth, reducing waveform distortion and restore real waveforms
Pass/Fail testing
Mathematical operation and FFT
X-Y format and display in dual windows
Ships from: China
Hantek DSO5072P Digital Storage Oscilloscope 70MHz 2Channels 1GSa/s 7inch TFT LCD
£321.95
£344.95
The Hantek DSO5072P brings you a range of great features to allow you to measure, trace and record your electrical issues. Ideal for Diagnostic and Repair work, the ability to either record your data to USB or connect to your PC for live data capture gives you a range of flexibility. With its large 7 inch WVGA display you can see results clearly. Hantek digital oscilloscopes offer an excellent price/performance ratio.
The DSO 5000 series offers twelve versions of digital oscilloscopes with the 60, 70, 100 and 200 MHz bandwidths. The main features of the DSO 5072P model are the 1GS/s maximum sampling rate, 24K sampling memory, USB host on the front USB panel (data storage possibility), connectivity for long-distance control by PC (software included) and external trigger. Standard delivery includes two 60 MHz passive probes 1:1 and 10:1.
Use our info link at the top of the description to get the latest software.
We will send you links for the latest software upon purchase.
Features:
70 MHz bandwidth.
1GSa/s Real Time sample rate.
Large (7.0-inch) WVGA(800x480) colour display.
Built-in memory for measurement storage: 2 GB
Record length up to 40K.
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
USB host and device connectivity, standard.
32 automatic measurements.
Four math functions, including FFTs standard.
Supplied with MSScope software for PC real-time analysis.
Specifications
Click to view
Full Specifications
×
Model
DSO5202P
DSO5102P
DSO5072P
Acquisition
Sample Rate
Real-Time Sample: 1GS/sEquivalent Sample: 25GS/s
Acquisition Modes
Normal
Normal data only
Pea'k Detect
High-frequency and randon glitch capture
Average
Waveform Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling
AC, DC, GND
Inputs Impedance
1MΩ±2% II20pF±3pF
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factor
1X, 10X, 100X, 1000X
Maximum Input Voltage
CAT I and CAT II: 300VRMS (10×), Installation Category;CAT III: 150VRMS (1×);Installation Category II: rated at 20dB/decade above 100kHz to 13V Peak AC at 3MHz* and above. For non-sinusoidal waveforms, Peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V.If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range
500MS/s--1GS/s
Waveform Interpolation
(sin x)/x
Record Length
40'K
SEC/DIV Range
DSO5202P4ns/div to 40s/div
DSO5102P/DSO5072P4ns/div to 40s/div
Sample Rate andDelay Time Accuracy
±50ppm(at over any ≥1ms time interval)
Position Range
DSO5202P2ns/div to 10ns/div;(-4div x s/div) to 20ms;
DSO5102P/DSO5072P20ns/div to 80us/div; (-8div x s/div) to 40ms;200us/div to 40s/div; (-8div x s/div) to 400s
Incremental Time Measurement Accuracy (Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);Sample interval = s/div ÷ 200
Vertical
Vertical Resolution
8-bit resolution, all channel sampled simultaneously
Position Range
2mV/div to 200mV/div, ±2V200mV/div to 5V/div, ±50V
Bandwidth
DSO5202P100MHz
DSO5102P100MHz
DSO5072P70MHz
Rise Time at BNC( typical)
DSO5202P3.5ns
DSO5102P3.5ns
DSO5072P5ns
Analogue Bandwidth in Normal andAverage modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math
+, -, *, /, FFT
FFT
Windows: Hanning, Flatop, Rectangular, Bartlett, Blackman;1024 sample point
Bandwidth Limit
20MHz
Low Frequency Response (-3db)
≤10Hz at BNC
DC Gain Accuracy
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types
Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source
CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes
Auto, Normal, Single
Coupling Type
DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity(Edge Trigger Type)
DC(CH1,CH2):1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz;HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range
CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V;EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;EXT: ± (6% of setting + 40mV);EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical)
Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type
CH1, CH2: Pea'k-to-Pea'k amplitude of 2 divisions;EXT: 400mV;EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type
Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range
100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode
Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge.Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.Less than: The trigger point is the trailing edge.Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range
20ns ~ 10s
Slope Trigger
Slope Trigger Mode
Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.Less than: The oscilloscope triggers when the waveform slope is less than the set slope.Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range
20ns ~ 10s
Overtime Trigger
Over Time Mode
Rising edge or Falling edge
Time Range
20ns ~ 10s
Alternative Trigger
Trigger on CH1
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution
6 digits
Accuracy (typical)
±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range
AC coupled, from 4Hz Min to rated bandwidth
Signal Source
Pulse Width or Edge Trigger modes: all available trigger sourcesThe Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as trigger able events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement
Voltage difference between cursors: ΔVTime difference between cursors: ΔTReciprocal of ΔT in Hertz (1/ΔT)
Auto Measuerment
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Min, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type
7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution
800 horizontal by 480 vertical pixels
Display Contrast
Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical)
About 5Vpp into ≥1MΩ load
Frequency(typical)
1kHz
Power Supply
Supply Voltage
100-120VACRMS(±10%), 45Hz to 440Hz, CATII120-240VACRMS(±10%), 45Hz to 66Hz, CATII
Power Consumption
<30W
Fuse
2A, T rating, 250V
Environmental
Temperature
Operating: 32F to 122F (0C to 50C);Non-operating: -40F to 159.8F (-40C to +71C)
Cooling Method
Convection
Humidity
+104F or below (+40C or below): ≤90% relative humidity;106F to 122F (+41C to 50C): ≤60% relative humidity
Altitude
Operating: Below 3,000m (10,000 feet);Non-operating: Below 15,000m(50,000 feet)
Mechanical
Size
Length 385mm, Width 200mm, Height 245mm
Weight
3.5KG(with Packing); 2.08KG(without Packing)
Ships from: China
Hantek DSO5102P USB Digital Storage Oscilloscope 100MHz 1GSa/s 2 Channels
£324.95
The Hantek DSO5102P brings you a range of great features to allow you to measure, trace and record your electrical issues. Ideal for Diagnostic and Repair work, the ability to either record your data to USB or connect to your PC for live data capture gives you a range of flexibility. With its large 7 inch WVGA display you can see results clearly.Hantek digital oscilloscopes offer an excellent price/performance ratio. The DSO 5000 series offers twelve versions of digital oscilloscopes with the 60, 70, 100 and 200 MHz bandwidths. The main features of the DSO 5102P model are the 1GS/s maximum sampling rate, 24K sampling memory, USB host on the front USB panel (data storage possibility), connectivity for long-distance control by PC (software included) and external trigger. Standard delivery includes two 60 MHz passive probes 1:1 and 10:1. Comfortable and user-friendly layout of the control elements is underlined by a large 7inch colour TFT display with 800x480 point resolution.Use our info link at the top of the description to get the latest software.
We will send you links for the latest software upon purchase.
Features:
100 MHz bandwidth.
1GSa/s Real Time sample rate.
Large (7.0-inch) colour display,WVGA(800x480).
Built-in memory for measurement storage: 2 GB
Record length up to 40K.
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
USB host and device connectivity, standard.
32 automatic measurements.
Four math functions, including FFTs standard.
Supplied with MSScope software for PC real-time analysis.
Specifications:
Click to view
Full Specifications
×
Model
DSO5202P
DSO5102P
DSO5072P
Acquisition
Sample Rate
Real-Time Sample: 1GS/s Equivalent Sample: 25GS/s
Acquisition Modes
Normal
Normal data only
Pea'k Detect
High-frequency and randon glitch capture
Average
Waveform Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling
AC, DC, GND
Inputs Impedance
1MΩ±2% II20pF±3pF
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factor
1X, 10X, 100X, 1000X
Maximum Input Voltage
CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: rated at 20dB/decade above 100kHz to 13V Peak AC at 3MHz* and above. For non-sinusoidal waveforms, Peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range
500MS/s--1GS/s
Waveform Interpolation
(sin x)/x
Record Length
40'K
SEC/DIV Range
DSO5202P4ns/div to 40s/div
DSO5102P/DSO5072P4ns/div to 40s/div
Sample Rate and Delay Time Accuracy
±50ppm(at over any ≥1ms time interval)
Position Range
DSO5202P2ns/div to 10ns/div;(-4div x s/div) to 20ms;
DSO5102P/DSO5072P20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s
Incremental Time Measurement Accuracy (Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200
Vertical
Vertical Resolution
8-bit resolution, all channel sampled simultaneously
Position Range
2mV/div to 200mV/div, ±2V 200mV/div to 5V/div, ±50V
Bandwidth
DSO5202P100MHz
DSO5102P100MHz
DSO5072P70MHz
Rise Time at BNC( typical)
DSO5202P3.5ns
DSO5102P3.5ns
DSO5072P5ns
Analogue Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math
+, -, *, /, FFT
FFT
Windows: Hanning, Flatop, Rectangular, Bartlett, Blackman; 1024 sample point
Bandwidth Limit
20MHz
Low Frequency Response (-3db)
≤10Hz at BNC
DC Gain Accuracy
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types
Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source
CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes
Auto, Normal, Single
Coupling Type
DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity (Edge Trigger Type)
DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range
CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical)
Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type
CH1, CH2: Pea'k-to-Pea'k amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type
Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range
100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode
Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range
20ns ~ 10s
Slope Trigger
Slope Trigger Mode
Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range
20ns ~ 10s
Overtime Trigger
Over Time Mode
Rising edge or Falling edge
Time Range
20ns ~ 10s
Alternative Trigger
Trigger on CH1
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution
6 digits
Accuracy (typical)
±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range
AC coupled, from 4Hz Min to rated bandwidth
Signal Source
Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as trigger able events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement
Voltage difference between cursors: ΔV Time difference between cursors: ΔT Reciprocal of ΔT in Hertz (1/ΔT)
Auto Measuerment
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Min, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type
7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution
800 horizontal by 480 vertical pixels
Display Contrast
Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical)
About 5Vpp into ≥1MΩ load
Frequency(typical)
1kHz
Power Supply
Supply Voltage
100-120VACRMS(±10%), 45Hz to 440Hz, CATII 120-240VACRMS(±10%), 45Hz to 66Hz, CATII
Power Consumption
<30W
Fuse
2A, T rating, 250V
Environmental
Temperature
Operating: 32F to 122F (0C to 50C); Non-operating: -40F to 159.8F (-40C to +71C)
Cooling Method
Convection
Humidity
+104F or below (+40C or below): ≤90% relative humidity; 106F to 122F (+41C to 50C): ≤60% relative humidity
Altitude
Operating: Below 3,000m (10,000 feet); Non-operating: Below 15,000m(50,000 feet)
Mechanical
Size
Length 385mm, Width 200mm, Height 245mm
Weight
3.5KG(with Packing); 2.08KG(without Packing)
Ships from: China
Hantek DSO5202P Digital Oscilloscope 200MHz 1GSa/s 2 Channels 7inch TFT LCD PC USB Electrical Tool
£400.95
The Hantek DSO5202P brings you a range of great features to allow you to measure, trace and record your electrical issues. Ideal for Diagnostic and Repair work, the ability to either record your data to USB or connect to your PC for live data capture gives you a range of flexibility. With its large 7 inch WVGA display you can see results clearly. Hantek digital oscilloscopes offer an excellent price/performance ratio.The DSO 5000 series offers twelve versions of digital oscilloscopes with 60, 70, 100 and 200 MHz bandwidths. The main features of the DSO 5202P model are the 1GS/s maximum sampling rate, 24K sampling memory, USB host on the front USB panel (data storage possibility), connectivity for long-distance control by PC (software included) and external trigger. The pack includes two 60 MHz passive probes 1:1 and 10:1 suitable for most tasks.Use our info link at the top of the description to get the latest software.
We will send you links for the latest software upon purchase.
Features:
200MHz bandwidths.
1GSa/s Real Time sample rate.
Large (7.0-inch) color display,WVGA(800x480).
Record length up to 40K.
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
USB host and device connectivity, standard.
32 automatic measurements.
Four math functions, including FFTs standard.
Supplied with MSScope software for PC real-time analysis.
Specifications:
Click to view
Full Specifications
×
Model
DSO5202P
DSO5102P
DSO5072P
Acquisition
Sample Rate
Real-Time Sample: 1GS/s Equivalent Sample: 25GS/s
Acquisition Modes
Normal
Normal data only
Pea'k Detect
High-frequency and randon glitch capture
Average
Waveform Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling
AC, DC, GND
Inputs Impedance
1MΩ±2% II20pF±3pF
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factor
1X, 10X, 100X, 1000X
Maximum Input Voltage
CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: rated at 20dB/decade above 100kHz to 13V Peak AC at 3MHz* and above. For non-sinusoidal waveforms, Peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range
500MS/s--1GS/s
Waveform Interpolation
(sin x)/x
Record Length
40'K
SEC/DIV Range
DSO5202P4ns/div to 40s/div
DSO5102P/DSO5072P4ns/div to 40s/div
Sample Rate and Delay Time Accuracy
±50ppm(at over any ≥1ms time interval)
Position Range
DSO5202P2ns/div to 10ns/div;(-4div x s/div) to 20ms;
DSO5102P/DSO5072P20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s
Incremental Time Measurement Accuracy (Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200
Vertical
Vertical Resolution
8-bit resolution, all channel sampled simultaneously
Position Range
2mV/div to 200mV/div, ±2V 200mV/div to 5V/div, ±50V
Bandwidth
DSO5202P100MHz
DSO5102P100MHz
DSO5072P70MHz
Rise Time at BNC( typical)
DSO5202P3.5ns
DSO5102P3.5ns
DSO5072P5ns
Analogue Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math
+, -, *, /, FFT
FFT
Windows: Hanning, Flatop, Rectangular, Bartlett, Blackman; 1024 sample point
Bandwidth Limit
20MHz
Low Frequency Response (-3db)
≤10Hz at BNC
DC Gain Accuracy
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types
Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source
CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes
Auto, Normal, Single
Coupling Type
DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity (Edge Trigger Type)
DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range
CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical)
Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type
CH1, CH2: Pea'k-to-Pea'k amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type
Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range
100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode
Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range
20ns ~ 10s
Slope Trigger
Slope Trigger Mode
Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range
20ns ~ 10s
Overtime Trigger
Over Time Mode
Rising edge or Falling edge
Time Range
20ns ~ 10s
Alternative Trigger
Trigger on CH1
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution
6 digits
Accuracy (typical)
±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range
AC coupled, from 4Hz Min to rated bandwidth
Signal Source
Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as trigger able events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement
Voltage difference between cursors: ΔV Time difference between cursors: ΔT Reciprocal of ΔT in Hertz (1/ΔT)
Auto Measuerment
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Min, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type
7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution
800 horizontal by 480 vertical pixels
Display Contrast
Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical)
About 5Vpp into ≥1MΩ load
Frequency(typical)
1kHz
Power Supply
Supply Voltage
100-120VACRMS(±10%), 45Hz to 440Hz, CATII 120-240VACRMS(±10%), 45Hz to 66Hz, CATII
Power Consumption
<30W
Fuse
2A, T rating, 250V
Environmental
Temperature
Operating: 32F to 122F (0C to 50C); Non-operating: -40F to 159.8F (-40C to +71C)
Cooling Method
Convection
Humidity
+104F or below (+40C or below): ≤90% relative humidity; 106F to 122F (+41C to 50C): ≤60% relative humidity
Altitude
Operating: Below 3,000m (10,000 feet); Non-operating: Below 15,000m(50,000 feet)
Mechanical
Size
Length 385mm, Width 200mm, Height 245mm
Weight
3.5KG(with Packing); 2.08KG(without Packing)