Hantek DSO5072P Digital Storage Oscilloscope 70MHz 2Channels 1GSa/s 7inch TFT LCD

£337.95
£337.95

Ships from our: China Warehouse.

The item will be delivered between 12 and 20. View our shipping info page for more information.

Delivery to most countries

Product description

The Hantek DSO5072P brings you a range of great features to allow you to measure, trace and record your electrical issues. Ideal for Diagnostic and Repair work, the ability to either record your data to USB or connect to your PC for live data capture gives you a range of flexibility. With its large 7 inch WVGA display you can see results clearly. Hantek digital oscilloscopes offer an excellent price/performance ratio.

The DSO 5000 series offers twelve versions of digital oscilloscopes with the 60, 70, 100 and 200 MHz bandwidths. The main features of the DSO 5072P model are the 1GS/s maximum sampling rate, 24K sampling memory, USB host on the front USB panel (data storage possibility), connectivity for long-distance control by PC (software included) and external trigger. Standard delivery includes two 60 MHz passive probes 1:1 and 10:1.

Use our info link at the top of the description to get the latest software.

We will send you links for the latest software upon purchase.

Features:

  • 70 MHz bandwidth.
  • 1GSa/s Real Time sample rate.
  • Large (7.0-inch) WVGA(800x480) colour display.
  • Built-in memory for measurement storage: 2 GB
  • Record length up to 40K.
  • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
  • USB host and device connectivity, standard.
  • 32 automatic measurements.
  • Four math functions, including FFTs standard.
  • Supplied with MSScope software for PC real-time analysis.
Previous Product Next Product

Specifications

Model DSO5202P DSO5102P DSO5072P
Acquisition
Sample Rate Real-Time Sample: 1GS/s
Equivalent Sample: 25GS/s
Acquisition Modes
Normal Normal data only
Pea'k Detect High-frequency and randon glitch capture
Average Waveform Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling AC, DC, GND
Inputs Impedance 1MΩ±2% II20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: rated at 20dB/decade above 100kHz to 13V Peak AC at 3MHz* and above.
For non-sinusoidal waveforms, Peak value must be less than 450V.
Excursion above 300V should be of less than 100ms duration.
RMS signal level including all DC components removed through AC coupling must be limited to 300V.
If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range 500MS/s--1GS/s
Waveform Interpolation (sin x)/x
Record Length 40'K
SEC/DIV Range DSO5202P
4ns/div to 40s/div
DSO5102P/DSO5072P
4ns/div to 40s/div
Sample Rate and
Delay Time Accuracy
±50ppm(at over any ≥1ms time interval)
Position Range DSO5202P
2ns/div to 10ns/div;
(-4div x s/div) to 20ms;
DSO5102P/DSO5072P
20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s
Incremental Time Measurement Accuracy
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Position Range 2mV/div to 200mV/div, ±2V
200mV/div to 5V/div, ±50V
Bandwidth DSO5202P
100MHz
DSO5102P
100MHz
DSO5072P
70MHz
Rise Time at BNC( typical) DSO5202P
3.5ns
DSO5102P
3.5ns
DSO5072P
5ns
Analogue Bandwidth in Normal and
Average modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math +, -, *, /, FFT
FFT Windows: Hanning, Flatop, Rectangular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
DC Gain Accuracy ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div];
Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability,
Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT):
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range CH1/CH2: ±8 divisions from center of screen;
EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy
is for signals having rise and fall times ≥20ns
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type CH1, CH2: Pea'k-to-Pea'k amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge.
Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Slope Trigger
Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger
Over Time Mode Rising edge or Falling edge
Time Range 20ns ~ 10s
Alternative Trigger
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz Min to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses
due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as trigger able events,
such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement Voltage difference between cursors: ΔV
Time difference between cursors: ΔT
Reciprocal of ΔT in Hertz (1/ΔT)
Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Min, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type 7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution 800 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical) About 5Vpp into ≥1MΩ load
Frequency(typical) 1kHz
Power Supply
Supply Voltage 100-120VACRMS(±10%), 45Hz to 440Hz, CATII
120-240VACRMS(±10%), 45Hz to 66Hz, CATII
Power Consumption <30W
Fuse 2A, T rating, 250V
Environmental
Temperature Operating: 32F to 122F (0C to 50C);
Non-operating: -40F to 159.8F (-40C to +71C)
Cooling Method Convection
Humidity +104F or below (+40C or below): ≤90% relative humidity;
106F to 122F (+41C to 50C): ≤60% relative humidity
Altitude Operating: Below 3,000m (10,000 feet);
Non-operating: Below 15,000m(50,000 feet)
Mechanical
Size Length 385mm, Width 200mm, Height 245mm
Weight 3.5KG(with Packing); 2.08KG(without Packing)

This is your slide's heading

Enjoy the flexibility

Primary button Secondary button

Friendly Service

Excellent service with a friendly touch.

Free Tracked Delivery to most destinations

Free delivery to UK, EU, US, AU and more.

Low Prices

If we are not the lowest please get in touch.

Latest and Greatest Tech

We are always searching for the latest products
Visa Mastercard American Express Discover Diners Club Apple Pay Google Pay Maestro Shop Pay Union Pay Klarna PayPal iDEAL Bancontact